Voltage Flicker Mitigation in Fast-Cycling Industrial Loads: Static Var Generator (SVG) vs SVC

Voltage Flicker Mitigation in Fast-Cycling Industrial Loads: Static Var Generator (SVG) vs SVC

2026-10-09
Voltage Flicker Mitigation in Fast-Cycling Industrial Loads: Static Var Generator (SVG) vs SVC Sub-second voltage fluctuations caused by rapid, cyclic reactive power demands represent one of the most destructive power quality anomalies in modern manufactu...
view detail
Why Is THDv Still High After THDi Improves? Source Impedance, Measurement and Corrective Actions

Why Is THDv Still High After THDi Improves? Source Impedance, Measurement and Corrective Actions

2026-09-29

Current harmonics improved but voltage distortion remains high? Learn how source impedance, upstream distortion and measurement conditions affect THDv.

view detail
What Is kVAR? How to Calculate Reactive Power for Power Factor Correction

What Is kVAR? How to Calculate Reactive Power for Power Factor Correction

2026-09-29

Learn what kVAR means, how to calculate reactive power from kW and power factor, and what to check before selecting capacitors, SVG or hybrid compensation.

view detail
Leading Power Factor at Night: Causes, Diagnosis and Correction Options

Leading Power Factor at Night: Causes, Diagnosis and Correction Options

2026-09-22

Leading power factor at light load may indicate capacitor overcompensation. Learn what to measure and when to evaluate an SVG or control adjustment.

view detail
AHF CT Installation: Placement, Polarity and Phase Mapping

AHF CT Installation: Placement, Polarity and Phase Mapping

2026-09-22

Incorrect CT placement, polarity or phase mapping can prevent an active harmonic filter from compensating correctly. Use this practical installation and commissioning checklist.

view detail
Can Active Harmonic Filters Work with Diesel Generators? A Practical Engineering Guide

Can Active Harmonic Filters Work with Diesel Generators? A Practical Engineering Guide

2026-09-16

Learn what to check before using an active harmonic filter with a diesel generator. Review source characteristics, CT placement, transfer logic and a commissioning test matrix for utility and generator operation.

view detail
High Neutral Current in Three-Phase Systems: Causes, Diagnosis and Solutions

High Neutral Current in Three-Phase Systems: Causes, Diagnosis and Solutions

2026-09-16

Discover why neutral current can remain high even with balanced phase loads. Learn how to distinguish imbalance, triplen harmonics and wiring issues, and when to assess a four-wire active harmonic filter.

view detail
Low Power Factor After Solar Installation: Causes and Correction Options

Low Power Factor After Solar Installation: Causes and Correction Options

2026-09-11

Find out why grid-side power factor can fall after rooftop solar begins operating. Compare inverter controls, capacitor banks and SVG options using a worked example and a site-data checklist.

view detail
THD vs TDD: How to Verify Harmonic Performance After AHF Installation

THD vs TDD: How to Verify Harmonic Performance After AHF Installation

2026-09-11

Learn how THDi and TDD differ, why measurement location matters, and what an AHF commissioning report should contain. Includes an illustrative calculation and a practical verification checklist.

view detail
APFC vs SVG vs Hybrid SVG: How to Choose a Reactive Power Compensation Solution

APFC vs SVG vs Hybrid SVG: How to Choose a Reactive Power Compensation Solution

2026-08-28

APFC, SVG and Hybrid SVG address reactive power compensation in different ways. Learn how to review load variation, power factor, harmonics, system wiring and site data before selecting a solution.

view detail