Leave Your Message

Static Var Generator

EXCELLENT For
Reactive Power Control

THREE LEVEL TOPOLOGY

Real Time Response

With Intelligent Algorithm

1118f7

ASVG detects the load current signal through CT, the DSP quickly tracks the command current, calculates the reactive power change rate through intelligent algorithms, and sends the data to the IGBT through the PWM signal. Finally, inductive or capacitive current is generated to achieve real-time dynamic reactive power compensation.

LEADING EDGE

TECHNICAL PERFORMANCE

Leading Edge 3 Topologyti1

3 Level IGBT Inverter Topology

Multi-Functional compensation: Reactive power, Imbalance & Harmonics

Precise and Stepless reactive power compensation;

Bi-Directional (capacitive and inductance) compensation;

PF adjustable: -1 ≤ Cosφ ≤ 1

Continuous PFC Correction

Best Compensation Product
For Dynamically Changing Loads

PFC Correctionjpx

● Both negative and zero sequence

● Mitigates neutral current

● Dynamic Response Time≤5.0ms.

● Transient Response Time≤50μs.

● Dynamic Reactive Power Compensation

● Continuous PFC correction 

● Excellent Low Voltage Characteristics

● Perfect Anti-Harmonic Characteristics

Multiple
Level Protection

left-textgky Static Var Generatorvvd
01qgi
028gg
038lj
010203

Modular Design

Revolutionary modular three level inverter reactive power management system.

Modular design that are available in wall-mounted, rack-mounted and free landing SVG/ASVG modules.

Modular installation with Comprise of single or multiple SVG/ASVG modules and HMI.

Flexible application with ultra-compact modular design, suitable for customized cabine.

Leading design technology

Dissipation Technology

Closed air duct design

DC speed control fan

Hybrid reactive power compensation system

Based on FFT and ADALINE Algorithm

Voltage level: 220V/ 400V/ 480V/ 690V

Connection: 3P3W/ 3P4W

Frequency: 50Hz/ 60Hz

pngimgaox
jqyzt9b

Intone Standard SVG

Capacity: 220V(171V~269V): 10/20/30/40/50kvar
400V(300V~456V): 30/50/75/100kvar
480V(356V~515V): 30/50/75/120kvar
690V(483V~793V): 50/100/150/200kvar
Efficiency: ≥97.5%
Type: Rack-type, Wall-mounted
Wiring method: 3P3W/3P4W (same unit)
Rated frequency: 50Hz/60Hz
Function: Power Factor Correction. Three phase balancing, Voltage regulation
Reactive compensation: Support LT and HT sensing


gg1gses26g

Intone Advanced SVG

Capacity:  220V(171V~269V): 10/20/30/40/50kvar
400V(300V~456V): 30/50/75/100kvar
480V(356V~515V): 30/50/75/120kvar
690V(483V~793V): 50/100/150/200kvar
Efficiency: ≥97.5%
Type: Rack-type, Wall-mounted
Wiring method: 3P3W/3P4W (same unit)
Rated frequency: 50Hz/60Hz
Function: Power Factor Correction. Three phase balancing, Harmonics Mitigation(2nd~25th), Voltage Regulation
Reactive compensation: Support LT and HT sensing

Intone Standard SVG

Intone Advanced SVG

Cases
POWER QUALITY

Discover Intone Power SVG's effectiveness in providing reactive power compensation and improving voltage stability across various applications.

65dff9csai
65dff9cgrp

CONTACT US NOW

Would you like to get information about Intone Power? We appreciate your interest and would be happy to advise you.
Simply give us some information so we can get in touch with you
  • Hotline 1
    021-33712042
  • Hotline 2
    +86 15021981917
  • E-mail
    sales@intonepower.com
  • Address
    CSG Industrial Park, Song Jiang Distrisct, Shanghai, China
    • • Charges vary depending on service provider and country/region